An inter-city structure had been demolished and the site was being repurposed to build a Canopy for an exhibit. Micro-Piles were originally specified bur the Engineer, Intech, value engineered the project due to suspect soil conditions and potential issues with subsurface obstructions.
Project Summary:
- Helical Pile Type: SS 175 (1 3/4″ square shaft) transitioning to 2 7/8″ Pipe
- # of Helical Piles: 21
- Location: Philadelphia, PA
- Installation Depth: 11′ to 14′
- Helix Plates/Ultimate Pile Capacity: 8″ 10″ 12″ / 14 Kips 7,500 ft-lbs.Torque
- Equipment Used: CAT 315 Excavator
- Challenge/Unique Aspect: There were no soil borings but a prior structured had been demoed and the site had not been properly remediated. Helicals were used as a cost-saving alternative to micro-piles and to fight through sub-surface debris.
- Engineer/Architect: Keast & Hood- Structural Engineers
Geostructures Inc. – Inspectors