SPLEX

Danbro provided a tieback design for sheeting inside an existing building using 1 3/4″ and 2″ square shaft (14′ cut).

Project Summary:

    • Helical Pile Type: 1.75″ and 2″ SQ.Shaft
    • Location: Landover, MD
    • Installation Depth: 20′ to 25′ installation length
    • Helix Plates/Ultimate Pile Capacity: 56 – 76 K Design Loads and 62 – 78 K Design Loads
    • Equipment Used: 30 ADS Drivehead with Tieback bracket
    • Challenge/Unique Aspect: Renovation took place inside an existing building overcoming access and mobilizations limitations.
    • Danbro Installer: Clark Construction
    • Engineer/Architect: Clark Construction S.O.E, Engineer